• 011 25161151
  • info@afcl.com
  • Mon – Sat: 10:00 am – 6:00 pm
Albartross FIne Chemicals Pvt. Ltd. Albartross FIne Chemicals Pvt. Ltd.
  • Home
  • About Us
  • Our Mission
  • Our Services
    • Services
    • Vendor Qualification
    • What to Expect
  • Products
    • Cooling Water Treatment Additives
    • Boiler Water Treatment Additives
    • Descalant / Passivators
    • Pikling Inhibitor / Foaming Compound
    • Acid Inhibitors for Indl. Cleaning
    • R.O Water Additive
    • Potable Water Additive
    • Fuel Additive
  • Contact Us

ARC-DS 1014 pH BOOSTER

Alkalinity Builder     ARC-DS 1014     pH BOOSTER FOR A VARIETY OF WATER SYSTEMS DESCRIPTION: ARC-DS 1014  is a concentrated liquid blend of alkaline materials designed for use in systems containing waters of low pH and low hardness. Primary application to acidic influent water will stabilize pH within the proper […]
Read More

ARC-DS 1013 Dispersant For Normal Conditions

Scale Preventive for Boiler     Albatross ARC-101 Range     ARC-1011, 1012, 1013, 1015     Used as Scale Preventive & Sludge Conditioner in boiler     An Ideal Solution to prevent Scaling Problems in Boiler PROBLEM SCALE Scale is an extremely hard substance created when mineral salts come out of solution as […]
Read More

ARC-1012 (XL) Scale Preventive & Sludge Conditioner

Albatross ARC-101 XL Range     ARC-1011 XL, 1012 XL, 1013 XL, 1015 XL     Used as Scale Preventive & Sludge Conditioner in boiler     An Ideal Solution to prevent Scaling Problems in Boiler PROBLEM SCALE Scale is an extremely hard substance created when mineral salts come out of solution as […]
Read More

ARC-DS 1011 Scale Preventive & Sludge Conditioner

Albatross ARC-101 XL Range     ARC-1011 XL, 1012 XL, 1013 XL, 1015 XL     Used as Scale Preventive & Sludge Conditioner in boiler     An Ideal Solution to prevent Scaling Problems in Boiler PROBLEM SCALE Scale is an extremely hard substance created when mineral salts come out of solution as […]
Read More

Boiler Type

CARRYOVER CONTROL TYPES OF CARRYOVER Carryover is caused by two mechanisms, priming and foaming. Priming is the sudden violent eruption of boiler water, which is carried along with steam out of the Boiler, usually caused by mechanical conditions. One of the major causes is a sudden increase in the steam […]
Read More

Combined Heat transfer process

In most of the engineering applications, however, heat is transferred in successive steps by similar or different mechanisms. For instance, let us consider the case of heating of water in a tube laid in a heat exchanger (or cooling of hot fluid in shell by CW). The water will receive […]
Read More

Introduction

Heat is the thermal energy transit from one system to another. The thermal energy can originate from any kind of energy according to the first law of thermodynamics. Transfer of heat is due to unique property of matter, temperature, and is governed by second law of thermodynamics, which dictates that […]
Read More

Heat Transfer in Cooling Tower

Two kind of heat transfer occur within the tower between warm water and air. Latent heat of vaporization: Some of the liquid changes to vapor with the absorption of heat. This energy, called the latent heat of vaporization, is that necessary to overcome the attractive forces between molecules in the […]
Read More

Variable affecting performance of CT Heat transfer – Cooling Tower

The rate at which heat is transferred in a cooling tower depends upon four factors: the area of the water surface in contact with air; the relative velocity of air and water; the time of contact between air and water; the difference between the wet bulb temperature of the inlet […]
Read More

Heat transfer within cooling system (heat exchanger)

The process represented in the above figure (1.1) is one in which hot fluid is cooled by water, which itself heated without any loss of exchanged heat. Industrial heat exchangers consist of a number of tubes enclose in a shell. Exchangers with cooling water in the tubes, and hot product […]
Read More
1 … 32 33 34 35 36 37

Recent Posts

  • Duel Casino explained – security guide and safety overview
  • Download Melbet App Latest Version: Payment Methods, Bonuses & Mobile Guide
  • Melbet App Play Store Download Guide 2026 – Install, Register & Get Mobile Bonuses
  • MWOS Betting Online MWOS: Quick Sessions, Crash Games, and the Zimbabwe Mobile Experience
  • SkyCrown Casino: Schnelle Sessions, Rasche Spins und die Kunst des Five-Minute Play

Recent Comments

    Popular Posts

    Categories

    • Acid Inhibitors for Indl. Cleaning
    • Boiler Water Treatment Additives
    • Chiller Water Treatment Additives
    • Cooling Water Treatment Additives
    • Descalant / Passivators
    • Fuel Additive
    • Pikling Inhibitor / Foaming Compound
    • Potable Water Additive
    • R.O Water Additive
    • Uncategorized
    • Water Treatment

    ALBATROSS FINE CHEM PRIVATE LIMITED
    (AN ISO 9001:2015 and ISO 14001:2015 CERTIFIED COMPANY)
    CIN No. U74899DL1995PTC067165
    40 D.L.F. INDUSTRIAL AREA, ALISHAN BUILDING, 3rd FLOOR,
    KIRTI NAGAR, NEW DELHI–110015 (INDIA)

    Useful Links

    • Services
    • Vendor Qualification
    • What to Expect
    • Contact Us

    Product Line

    • Cooling water treatment additives
    • Boiler water treatment additives
    • Descalant / passivators
    • Pikling inhibitor / Foaming compound
    • Acid inhibitors – Indl. cleaning
    • R.O. Water additive
    • Potable water additive
    • Fuel additive

    AFCL

    • About Us
    • Services
    • What to Expect
    • Vendor Qualification
    • Blog
    • Our Book Store
    • Contact Us
    • CSR Policy
    Copyright 2020 AFCL, All rights reserved. | Powered by Caba Innovatives

    • Cooling water treatment additives
    • Boiler water treatment additives
    • Descalant / passivators
    • Pikling inhibitor / Foaming compound
    • Acid inhibitors – Indl. cleaning
    • R.O. Water additive
    • Potable water additive
    • Fuel additive